Nano Coulomb Breath Analyser, Sunvou

Sunvou  ·  FeNO by Sunvou

Nano Coulomb Breath Analyser


The Sunvou Nano Coulomb breath analyser range measures exhaled nitric oxide and, on the CA2122 and TM2120 models, exhaled carbon monoxide. Three models are offered: the PC connected CA2122, the portable touchscreen TM2120, and the entry level TM1100 for FeNO50 only. The range covers large, small and upper airway measurement, with online, offline and tidal detection options on the CA2122.

  • Online, offline and tidal modes
  • Large, small and upper airway
  • Self calibration and gas check
Request a quotation Ask on WhatsApp

Installation, clinical application training and 24 months warranty are included. Manufacturer brochure available on request.

Key features

  • Measures exhaled NO, and CO on the CA2122 and TM2120 models
  • Covers large airway, small airway and upper airway measurement sites
  • Online, offline and tidal detection options on the CA2122
  • Reports FeNO50, FeNO200/CaNO, nasal FnNO and FeCO depending on model
  • Tidal and offline modes allow testing of young children and ICU patients
  • Quality control by cylinder gas, self calibration and device auto-check
  • Touchscreen display with on board storage on the TM2120 and TM1100
  • Low cross sensitivity to 16 common interference gases in human breath

Specifications

ModelsSunvou CA2122, TM2120 and TM1100
Measured parametersFeNO50, FeNO200/CaNO, FnNO and FeCO by model; TM1100 measures NO only
Detection optionsOnline, offline and tidal (CA2122), online (TM2120, TM1100)
Measurement rangeNO 0 to 3000 ppb, CO 0 to 250 ppm
Lowest detection limitNO 3 ppb, CO 2 ppm (CA2122) or 0.5 ppm (TM2120)
Precision and linearityRelative standard deviation less than 10 per cent, R2 greater than 0.99
NO accuracyWithin 3 ppb below 30 ppb, within 10 per cent at 30 ppb and above
Analysis timeNO 70 sec and CO 80 sec (CA2122), NO 20 sec (TM2120, TM1100)
Dimensions75 x 210 x 88 mm (CA2122), 195 x 145 x 80 mm (TM2120), 140 x 100 x 78 mm (TM1100)
Weight2.0 kg (CA2122), 1.0 kg (TM2120), 0.7 kg (TM1100)
Display and storage5 inch touchscreen with 5000 measures (TM2120), 4.3 inch touchscreen with 1000 measures (TM1100)
Analyser and sensor lifeAnalyser 5 years or 50000 measures, sensor 2 years
Operating conditions5 to 35 degrees C, 80 per cent RH or less, 700 to 1060 hPa
Power input100 to 240 V, 50 to 60 Hz, 0.6 A

Specifications are taken from the manufacturer documentation and may change without notice. Ask us for the current datasheet before you specify or tender.

Typical applications

  • Asthma
  • COPD
  • Allergic rhinitis
  • Assessment of type 2, non type 2 and mixed airway inflammation

Talk to us

Let us help you specify the right system.

Tell us the clinical requirement. We will recommend a configuration, arrange a demonstration at your facility and prepare a detailed quotation.

Call WhatsApp Enquire