VPM 50


The VPM 50 is a compact 12.1 inch patient monitor for adult, paediatric and neonatal patients. It measures ECG, SpO2, NIBP, two temperature channels, respiration and pulse rate, shows five waveforms with heart rate, and weighs 1.5 kg so it can be carried or used in an ambulance.

  • 96 hours of trend storage
  • 3 or 5 lead ECG, SpO2, NIBP
  • 1.5 kg, ambulance suitable
Request a quotation Ask on WhatsApp

Installation, clinical application training and 24 months warranty are included. Manufacturer brochure available on request.

Key features

  • 12.1 inch colour TFT with multi channel waveform display
  • Five waveforms displayed with heart rate
  • Standard parameters: 3/5 lead ECG, SpO2, NIBP, 2 temperature and pulse rate
  • Suitable for adult, paediatric and neonatal patients
  • Weighs 1.5 kg, suitable for ambulance use
  • Connects to a central monitoring system
  • Tabular and graphical trends held in memory
  • Runs about 3 hours on the internal lithium ion battery

Specifications

Display12.1 inch colour TFT, 5 waveforms with heart rate
ECG3 or 5 leads, leads I, II, III, aVR, aVL, aVF, V
ECG frequency responseDiagnostic 0.05 to 90 Hz, monitor 0.5 to 35 Hz, surgery 1 to 15 Hz
SpO20 to 100 per cent, dual wavelength LED, accuracy plus or minus 2 per cent for 70 to 99 per cent
Pulse rateAdult 15 to 300 bpm, paediatric 15 to 350 bpm, accuracy plus or minus 1 bpm or 1 per cent
NIBPOscillometric during inflation, adult 40 to 270 mmHg, paediatric 40 to 240 mmHg, neonate 40 to 135 mmHg
NIBP accuracyPlus or minus 2 mmHg or 2 per cent of reading, cycle less than 40 sec typical
Temperature2 channels, 0 to 50 degrees C, accuracy plus or minus 0.1 degrees C, YSI 400 and YSI 700 probes
Respiration rateAdult 0 to 120 rpm, neonate and paediatric 0 to 150 rpm, accuracy plus or minus 2 breaths per min
Trends96 hours at 30 second intervals with an NIBP reading every 5 minutes, tabular and graphical
PowerAC 100 to 240 V, 50/60 Hz, 35 W
Battery14.8 V, 2200 mAh Li-ion, recharge 4.5 hours, about 3 hours operation
Dimensions (L x B x T)200 x 100 x 200 mm
Weight1.5 kg